Portée maximale: 200A~900A Température de stockage: -40 - 125
Tension de sortie (linéaire): Vout= (Uc/5)·(V0+G·IP) Sortie nulle: 2,5
Consommation actuelle: 13 Résistance de charge: 10
Capacité de charge: 1 Compensation zéro électrique: ±2.5
Surligner:

900A Current Transducers

,

3us Response Current Transducers

NACA.XXXL-S6/SP5VA Current Transducers

Product Details

product manual

NACA XXXL-S6/SP5VA series current sensor is suitable for accurate measurement of AC, DC and pulse current isolation. The primary side and the secondary side are completely insulated during measurement.
 

Performance requirements
parameter name symbol unit parameter condition
Minimum Typical value Max
Electrical parameters
Maximum range IP A 200A~900A For more details, please contact CRRC
Storage temperature TS °C -40   125  
voltage UC V 4.75 5 5.25  
Output voltage (linear) Vout V Vout=(Uc/5)·(V0+G·Ip) @UC
Sensitivity G mV/A 2000/Ip @UC=5V
Zero output VO V   2.5   @UC=5V
Current consumption IC mA   13 15 @UC=5V, No load on Vout
Load Resistance RL 10      
Load capacitance CL nF   1 10  
Output internal resistance ROUT Ω     1 DC
Performance parameter
Zero output error X0 %   ±0.65   @TA=25℃, UC=5V
  ±0.9   @-40℃<TA<125℃, UC=5V
Sensitivity error   %   ±2.25   @TA=25℃, UC=5V, 200A≤Ip≤800A
  ±2.5   @TA=25℃, UC=5V, Ip = 900A
  ±3.25   @-40℃<TA<125℃, UC=5V,200A≤Ip≤800A
  ±3.75   @-40℃<TA<125℃, UC=5V, Ip = 900A
Electrical zero offset FLY mV   ±2.5    
Magnetic zero offset FROM mV   ±3    
Proportional error .R %   0.5    
Linearity error εL % -1   1 of full range
Response time tr μs   3    
bandwidth BW kHz 40     @ -3dB
Phase difference ∆φ ° -4     @DC to 1kHz

 

Dimensions
Series size
900A Current Transducers For DC Current Measurement 0900A Current Transducers For DC Current Measurement 1

 

Mechanical parameters Remarks
● Plastic case PA 66 GF 25
● Magnetic core FeSi wound core
● Mass 50g

900A Current Transducers For DC Current Measurement 2

● VOUT>VO when IP flows in the positive direction (see arrow on drawing)

Electrical Interface
900A Current Transducers For DC Current Measurement 3

 

 

Procurement information

 

1. Products can be customized according to your needs. You are welcome to provide physical samples or detailed process drawings to design, produce and process.

 

2. If there is no special requirement, our company will assign logistics distribution and deliver the goods to customer factory

 

3. Payment method: delivery after payment, which can be negotiated according to the specific order quantity.

 

4. The response time of the number of customers should not exceed 8 working hours.

 

5. Emergency on-site service time shall not exceed 24 hours.

 

6. Provide emergency support for customer's urgent shortage of spare parts.

Coordonnées
Xiamen Sincery Im.& Ex. Co., Ltd.

Personne à contacter: Miss. Elaine

Téléphone: +86 18150151931

Télécopieur: 86-592-2611505

Envoyez votre demande directement à nous (0 / 3000)

Autres Produits